Automatic Voltage Transformer Burden With Air Insulation

Brand Name : HNMC

Model Number : FYC series

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 30 sets per month

Delivery Time : 30-45 days

Packaging Details : Wooden Package

Rated Current : 1A, 5A

Power factor : 0.8, 1.0

Accuracy class : 3

Rated Frequency : 50/60 HZ

Rated voltage : 110V, 100V, 110V/√3V, 100V/√3V

Insulation : Air

Contact Now

Manual or Automatic CT VT Burden box FYC series

FYC47-49 CT Burden

Technical Parameter

Rated Current: 5A, 1A
Power Factor and Rated Burden:

COSΦ=0.8: 5VA, 10VA, 15VA, 20VA, 30VA

COSΦ=1.0: 1VA, 2VA, 5VA

Accuracy Class: ±3%
Operation Range: (1%-200%). In
Test Cable Resistance: 0.02Ω
Frequency: 50Hz
Withstand Voltage: 2kV/1min
Insulation: Air
Operating Mode: Continue at 200%.In
Control Mode: Manual and computer controllable (protocol provided)
Cooling Mode: Fan

FYC95 PT Burden

Technical Parameters

Rated Voltage: 110V, 100V, 110V/√3V, 100V/√3V
Power Factor and Rated Burden:

COSФ=0.8: 10VA, 25VA, 50VA, 100VA (Total burden:185VA)

COSФ=1.0: 1VA, 2.5VA, 5VA, 10VA (Total burden:18.5VA)

Accuracy Class: ±3%
Operation Range: (20%-190%). Un
Frequency: 50Hz
Withstand Voltage: 2kV/1min
Insulation: Air
Operating Mode: Continue at 190%.Un
Control Mode: Manual and computer controllable (protocol provided)
Cooling Mode: Fan

Technical service

Much experienced technical team will provide strong technical support for your market development. We can provide support on customization, maintenance, device design, construction scheme, design optimization, and product development.

Quality control

We have professional quality control team. Our quality control covers materials, production procedure, finished product inspection, final inspection before loading, inspection report.


Product Tags:

Automatic Voltage Transformer Burden

      

110V Voltage Transformer Burden

      

3% transformer testing equipment

      
Best Automatic Voltage Transformer Burden With Air Insulation wholesale

Automatic Voltage Transformer Burden With Air Insulation Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhengzhou Great Electric Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)